User manual
Table Of Contents
- User Manual
- Starlink SL9003Q
- Digital Studio Transmitter Link
- WARRANTY
- SL9003Q Manual Dwg # 602-12016-01 R: G Revision Levels:
- Using This Manual - Overview
- Section 1 System Features and Specifications
- Section 2 Quick Start
- Section 3 Installation
- Section 4 Operation
- Section 5 Module Configuration
- Section 6 Customer Service
- Section 7 System Information
- Table of Contents
- List of Figures
- List of Tables
- 1 System Features and Specifications
- 2 Quick Start
- 3 Installation
- 4 Operation
- 7.1 Introduction
- 7.2 Front Panel Operation
- 4.3 Screen Menu Navigation and Structure
- 7.4 Screen Menu Summaries
- 4.4.1 Meter
- 4.4.2 System: Card View
- 4.4.3 System: Power Supply
- 4.4.4 System: Info
- 4.4.5 System: Basic Card Setup
- 4.4.6 Factory Calibration
- 4.4.7 SYSTEM: UNIT-WIDE PARAMS
- 4.4.8 System: Date/Time
- 4.4.9 System: Transfer
- 4.4.10 System: External I/O (NMS)
- 4.4.11 Alarms/Faults
- 4.4.12 Radio: Modem Status (QAM)
- 4.4.13 Radio TX Status
- 4.4.14 Radio RX Status
- 4.4.15 Radio TX Control
- 4.4.16 Radio RX Control
- 4.4.17 Radio Modem (QAM) Configure
- 4.4.18 Radio TX Configure
- 4.4.19 Radio RX Configure
- 4.4.20 Radio Modem/TX/RX Copy Function
- 4.5 Intelligent Multiplexer PC Interface Software
- 4.6 NMS/CPU PC Interface Software
- 5 Module Configuration
- 6 Customer Service
- 7 System Description
- 8 Appendices
- Appendix A: Path Evaluation Information
- Appendix B: Audio Considerations
- Appendix C: Glossary of Terms
- Appendix D: Microvolt – dBm – Watt Conversion (50 ohms)
- Appendix E: Spectral Emission Masks
- Appendix F: Redundant Backup with TP64 and TPT-2 Transfer Panels
- Appendix G: Optimizing Radio Performance For Hostile Environments
- Appendix H: FCC APPLICATIONS INFORMATION - FCC Form 601
- Starlink SL9003Q & Digital Composite - 950 MHz Band

Section 2: Quick Start 2-11
Moseley SL9003Q 602-12016 Revision G
2.6.2. Composite
The composite channel is located on the Composite MUX (4-Port) module (see Fig. 2-4).
Table 2-2 Composite MUX (4-Port) Typical Settings
Input Level
3.5 Vp-p for 100% modulation
Input Type
BNC female, unbalanced, 100kohms
Output Level
3.5 Vp-p for 100% modulation
Output Type
BNC female, unbalanced, Low-Z (<5 ohms)
Output Load
75 ohms or greater, maximum load capacitance 0.047
μF. Maximum recommended cable length 100ft RG-
58A/U
2.6.3. Data Channels
2.6.3.1. Data Channels on the Encoder/Decoder Module
The normal serial data channels are located at the Encoder and Decoder (labeled
"DATA"). For 4 channel systems, ENC1 contains Data Channel 1 and ENC2 contains
Data Channel 2 (see Fig.2-2). Dip-switches located at the on Encoder/Decoder modules
configure the data channel rates and bit length.
Data Channel -
Encoder/Decoder Module
9-pin D male, RS-232 levels, Asynchronous 1200 baud, 8
bits, 1 start & 1-2 stop bits.
2.6.3.2. Data Channels on the Composite MUX (4-Port) module
The Composite MUX data channel is identified by "Ch. 1" on the module (see Fig.2-4).
Jumpers on the Composite modules configure proper null-modem operation (see
Section 5, Module Configuration, for changing the data channel configuration).
Data Channel - Composite
Mux
9-pin D male, RS-232, Set for:
300 baud, 8 bit, odd parity (default)
-OR- 1200 baud, no parity (optional)
2.6.3.3. Data Channels on the 6-Port MUX module
The 6-Port MUX is normally used in a Starlink STL system to provide an Ethernet IP
data link. The default port is labeled "Port 2".
Data Channel: 6-Port Mux