5-22 Section 5: Module Configuration
Moseley SL9003Q 602-12016 Revision G
To set “Map Faults-Relays”, perform the following steps:
On the SL9003Q Tx Main Menu
Use Up or Down arrow to select System
<Enter>
Scroll down to External I/O
<Enter>
Scroll down to Map Fault-Relays
<Enter>
Use left or right arrow to select Off or On for Map to Relays
<Enter>
<Escape>
<Escape>
Use left or right arrow to select Yes to save settings
<Enter>
In a Receiver
Relay 2 pins 5 (-) and 6 (+)
Any Fault or Alarm or Equipment Power Off
Relay 2 = Off (Set Open)
No Faults or Alarms and Equipment Power On
Relay 2 = On (Set Closed)
Relay 3 pins 3 (-) and 4 (+)
Receive RSL < -100dBm or Equipment Power Off
Relay 3 = Off (Set Open)
Receive RSL > -100dBm and Equipment Power On
Relay 3 = On (Set Closed)
Relay 4 pins 1 (-) and 2 (+)
Pre-BER > 1E-4 or Equipment Power Off
Relay 4 = Off (Set Open)
Pre-BER < 1E-4 and Equipment Power On
Relay 4 = On (Set Closed)