SETUP
Virtual Channels
Virtual Channel selection: Select the virtual channel 1-16 for configuration.
Virtual Channel Label: Used to identify the virtual channel source.
Virtual Channel Units: Label in engineering units, such as V = Volts,
A = Amps, W = Watts, etc.
Multiply Constant: Enter the value of the multiplier constant.
Analog 1 and 2: Number of Meter to use in Virtual Channel calculation.
NOTE: The value of the Virtual Channel will be calculated by multiplying Analog 1,
Analog 2 and the Multiply Constant together.
Alarms High: This option enables the “High Trip Point” email alarm.
Alarms Low: This option enables the “Low Trip Point” email alarm.
Alarms Exit: This option enables the emailing after exiting an alarm.
Email Addresses: This allows you to configure up to 8 emails to be sent
whenever the input goes above or below a set-point.
Log Device: This enables the email logging of this device.
Delay time: The delay is in (0 to 999) seconds. This option specifies the
wait time from when a value is out of range before an
alarm is activated.
Low trip point: This option specifies the LOW alarm set point.
High trip point: This option specifies the HIGH alarm set point.
NOTE: After any item has been changed, you MUST press the “Save Settings” button
for your changes to be saved.