ADMS 44.22 Installation and Operation Manual
OPERATION
4.15 Menu Mode
Menu Mode is an interactive text entry mode that allows the user to view and
change many of the most commonly accessed settings without having to refer to the
RS-232 command set documentation.
MM Enable Menu Mode (ACS 8.2)
Enters Menu Mode. Entering Menu Mode causes the main menu to be displayed.
1 - Sample Rate 48000.0
2 - Sample Clock Internal
3 - Sample Rate Conversion ---
4 - Mix Mode Overlap
5 - Analog Operating Level ---
6 - Dim Level ---
7 - Fade Rate 2.0
8 - Relay Pulse Length 1.0
9 - OC Pulse Length 1.0
10 - Silence Sensor Delay 5.0
11 - Silence Sensor Threshold -48.0
12 - Error Responses On
13 - Terminal Echo On
14 - Front Panel Lock Off
D - Set Factory Defaults
Q - Quit
Enter Choice:
At the prompt, enter the number corresponding to the setting you wish to
change, then press <Enter>. A submenu appears prompting you to enter a value for
the setting. For example, the following submenu appears when you enter ā1ā at the
main prompt:
Set Sample Rate (0 = 32kHz, 1 = 44.1kHz, 2 = 48kHz, 3 = 88.2kHz,
4 = 96kHz):
Enter the number corresponding to the desired value, then hit <Enter>. The
setting changes you are returned to the main menu. For settings 12 through 14, sim-
ply enter the setting number and hit <Enter> to toggle the value. Entering a āDā at the
main prompt loads the factory defaults (same as CDEF and PLF commands). Entering
Q at the main prompt exits menu mode and returns you to command control.