Specifications

e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
35
ADMS 44.22 Installation and Operation Manual
OPERATION
Bypassed O:-20.0 T:-50.0 R: 1.5
Digital Input 4
Bypassed O:-20.0 T:-50.0 R: 1.5
Analog/Digital Output 1
Bypassed O:-20.0 T:-50.0 R: 1.5
Analog/Digital Output 2
Bypassed O:-20.0 T:-50.0 R: 1.5
4.9 Preset Management Commands
CDEF Load Factory Default Settings (ACS 8.2)
Loads the factory default settings for the unit. The factory defaults for each
ADMS 44.22 control are described in the table below:
*Note: The state of the open collector outputs cannot be saved or loaded when the unit
Parameter Setting
Sample Rate 48k
Sample Clock Internal (Master)
Master ADMS (Slave)
Mix Mode Overlap
Fade Rate 2.0s
Relay Pulse Length 1.0s
OC Pulse Length 1.0s
Silence Sensor Delay 5s
Silence Sensor Threshold -48.0 dBFS
Error Response On (Master)
Off (Slave)
Terminal Echo On
Front Panel Lock Off
Analog Operating Level Pro
RelaysUnlatched
Open Collector Outputs* Unlatched (High/Off)
SRC Enable Enabled
Input Assignment In1>Out1 (only)
Dim Level -10dBFS
Output Monitor Source Output 1
ALC Enable Bypassed
ALC Target Output -20.0 dBFS
ALC Threshold -50.0 dBFS
ALC Ratio 1.5
EQ Enable, All Bands Bypassed
EQ Type, Band 1 Low Shelf
EQ Type, Band 2 Peaking
EQ Type, Band 3 High Shelf
EQ Gain, All Bands 0.0 dB
EQ Frequency, Band 1 20 Hz
EQ Frequency, Band 2 1.0 kHz
EQ Frequency, Band 3 20 kHz
EQ Q, All Bands 1.0