Specifications
e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
31
ADMS 44.22 Installation and Operation Manual
OPERATION
Response:
S[u]R,[yk1],[yk2],[yk3],[yk4]<CR><LF>
SO Display Open Collector Status (ACS 8.2)
Returns the current status of open collector outputs OC1 through OC9.
[yocn] 0 = Unlatched (High/Off); 1 = Latched (Low/On)
Response:
S[u]O,[yoc1],[yoc2],[yoc3],[yoc4],[yoc5],[yoc6],[yoc7],[yoc8],[yoc9]<CR><
LF>
SD Display AES Error Status
Returns the contents of the AES error register for digital Inputs 1 through 4.
Whenever an AES cyclical redundancy check (CRC), parity, eye-pattern, or
biphase error is detected on any digital input that is connected to Output 1, the
error is latched in an AES error detection register; errors detected on inputs not
connected to Output 2 are ignored. For units with ID=0, an SD messsage is
automatically sent to the terminal whenever the AES register status changes.
Once an AES error is latched for any given input, no additional SD messages
will be sent until the register is cleared with the AESR command. If no AESR
command is sent within 10s, then the AES error register is cleared and the LED
turned off.
[ydn] 0 = No Errors; 1 = Error
Response:
S[u]D,[yd1],[yd2],[yd3],[yd4]<CR><LF>
AESR Clear AES Error Register
Clears the contents of the AES error register, turns off the front panel AES Error
LED, and returns and SD message to confirm that the errors have been cleared.
[ydn] 0 = No Errors; 1 = Error
Response:
S[u]D,[yd1],[yd2],[yd3],[yd4]<CR><LF>
SRCD Display Sample Rate Converter Settings
Returns the sample rate converter settings for digital inputs 1 through 4 in a text-
readable format:
Digital Input 1 SRC: Enabled
Digital Input 2 SRC: Enabled
Digital Input 3 SRC: Enabled
Digital Input 4 SRC: Enabled<CR><LF>
OLD Display Analog Input Operating Levels
Returns the operating level settings for analog inputs 1 through 4 in a text-read-
able format:
Analog Input 1: Pro (+4dBu)
Analog Input 2: Pro (+4dBu)
Analog Input 3: Pro (+4dBu)