Specifications

e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
29
ADMS 44.22 Installation and Operation Manual
OPERATION
4.6 Query Commands
Poll Poll Units (ACS 8.2)
Queries the RS-232 bus to detect which units are connected. In a multi-drop
RS-232 setup, units respond with delays proportional to the Unit ID so that no
units will have their transmitters enabled at the same time. Units respond by
sending their Unit ID back to the terminal. For example, if ID=0 and ID=6 are
present, the units respond with:
0
RRR
6
RRR<CR><LF>
Note: The Unit ID prefix is not used with this command.
U Display Unit Name/Software Version (ACS 8.2)
Returns the name of the unit and the current DSP software version in the fol-
lowing text-readable format:
ADMS44.22
Software Version: 1.00<CR><LF>
Y Display Configuration Settings (ACS 8.2)
Returns a list of many of the unit’s configuration settings in the following text-
readable format:
Sample Rate 48000.0
Sample Clock Internal
Mix Mode Overlap
Fade Rate 2.0
Relay Pulse Length 1.0
OC Pulse Length 1.0
Silence Sensor Delay 5.0
Silence Sensor Threshold -48.0
Error Responses On
Terminal Echo On
Front Panel Lock Off
Unit ID 0
Baud Rate 57600
Power-up State User
GPI Remote
GPO Status
Master/Slave Master
Single/Dual Single<CR><LF>
SL Display Audio Switcher Status (ACS 8.2)
Returns the current status of the audio switcher. Line 1 of the response displays
which inputs are connected to Output 1, and line 2 displays which inputs are
connected to Output 2. For units with ID=0, the SL message is automatically
WEBSITE:
Visit our web site for
product updates and
additional information.