Specifications

e-mail:
support@broadcasttools.com
voice:
360.854.9559
fax:
866.783.1742
15
DAS 8.4 Plus Installation and Operation Manual
INSTALLATION
Glossary Of Command Notation:
Character String Meaning Allowable Values
u Unit ID 0-7
ii Input Number 01-08
o Output Number 1,2,3,4
oo Open Collectors 01 – 16
Set-up Commands:
*uCCx Ignore, set by switches
*uCEx Enable Error and Good Responses - Where x = Y to enable
and N = disable. In this mode, when a command is sent that
is in error, the unit will reply (possibly before receiving the
entire command) with “EEE.” If the command is sent cor-
rectly, the unit will reply with “RRR.”
*CDEF Reset to factory defaults
*uCIIttt Set “PIP” Programmable Pulse Stretcher Input Duration = ttt:
000 – 255 Off to 2.55 Seconds.
*uCIOiittt Ignore, send OK
*uCLx Lock Front Panel if x is “L”. Unlock Front Panel if x is “U”
*uCRtt Set Open Collector Momentary Pulse Length – tt:00-99 for
00 – 9.9 Seconds
*uCSAtttt Set digital data error and/or silence sensor time delay to tttt
seconds (0002 – 9999), 0000 = OFF
*uCSBtttt Set digital data error and/or silence sensor restore delay to tttt
seconds (0002 – 9999), 0000 = OFF
*uCSDttt Ignore, send OK
*uCST Ignore, send OK
*uCSVttt Ignore, send OK
*uMCnn Save current audio state as Macro # nn (01 à 08)
*uMInn Invoke macro # nn (01 à 08)
*uMM Enter menu mode if unit ID = 0
*uMS Ignore, send OK
*uN Ignore, send OK
Real Time Control Commands:
*uDxx Delay xx seconds before processing next command.
*uZx Echo character “x” to serial control port. Useful in debugging
command strings
Open Collector Output Control Commands:
*uOOrrL Latch open collector “rr”
*uOOrrF Unlatch open collector “rr”
*uOOrrP Pulse open collector “rr”
WEBSITE:
Visit our web site for
product updates and