Specifications

Mica Installation Planning Guide - Sept 2011
Page
30
The Broadcast Pix system can control a wide-range of Panasonic cameras, including the
AW-HE100, AW-PH400 and other Panasonic pan-tilt camera control systems.
This software option can control up to 12 different robotic cameras, each of which may have
up to 100 presets. Typical installations use a RS-422 configuration, which extends the maximum length
to 1,200 meters (4,000 feet). All cameras are configured in a daisy chain configuration where all control
cables are connected back at the Broadcast Pix server.
The single camera configuration, (option # 811) includes a DB 9-pin RS-232 to screw terminal RS-422 converter
which plugs into the server in either COM 1 or COM 2. From the screw terminal you may connect your first
camera using a standard RJ-45 connector, which Plugs directly into the camera. You may connect up to 2
convertors for 2 cameras, since there are only 2 RS-232 ports on the server. See below for the wiring diagram.
If controlling more than one camera, there is an optional 4 or 8 port Edgeport serial extender
(option #814 or #818) which plugs into a USB port on the server. It provides either 4 or 8 DB 9-pin
RS-422 connectors to accommodate a star configuration. See below for the wiring diagram.
Panasonic Camera Control Option #802 (RS-422)
422 Serial Cable
Mica
Com 1 or Com 2
Single Panasonic RS-422
Configuration:
Pin Function
3 TXD (A) -
7 TXD (B) +
8 RXD (A) -
4 RXD (B) +
5 GND
Function
TXD (A) -
TXD (B) +
RXD (A) -
RXD (B) +
GND
Pin Function
3 RXD (B) +
6 RXD (A) -
4 TXD (B) +
5 TXD (A) -
1 GND
2
7
8
RS-422 Terminal Connector to RJ-45 Pinout:
AW-HE100
DB 9-Pin Serial Cable to RJ-45 Pinout:
USB A-B Cable
Mica
Any USB Port
Panasonic RS-422 Edgeport
Star Configuration:
Edgeport
Pin Function
3 RXD (B) +
6 RXD (A) -
4 TXD (B) +
5 TXD (A) -
1 GND