User's Manual
5
Technical Specifications
Table 1 General Specifications
Indoor Unit (IDU) Outdoor Unit (ODU)
Size
17.5 x 14.9 x 3.5 in
(44.1 x 37.8 x 8.9 cm)
15.0 x 3.7 x 9.0 in
(38.1 x 22.9 x 9.2 cm)
Weight
11 lb (5 kg) 16.5 lb (7.5 kg)
Oper Altitude
15,000 ft 15,000 ft
Operating Temp
-20 - +55º C -20 - +55º C
Stor. Temp
-30 - +70º C -40 - +80º C
Relative Humidity
98% NC 100%
Power Req
105-260 VAC 50/60 Hz 48 VDC (supplied by IDU)
Ventilation Requirements
Fan inlet and outlets must have no
obstruction
Fins must be oriented vertically on
antenna mast
Specification
Frequency
1.99 – 2.7 GHz
(Pre-programmed with US 12 MHz and 17MHz BAS channel plans
including offsets)
Tuning Step Size
250KHz
Frequency Stability
+/- 5ppm max
Power Consumption
200W max
Recommended IDU-ODU Cable
100ft max
50 or 75 Ω cable (selectable)
Average Output Power
(1.99 – 2.7 GHz) FM COFDM
6 W (typical) 5 W (typical)