Installation Sheet
91840 Rev. A
Escutcheon Installation
Secure backplate (2) to rough-in body (3) using 4
screws (4) provided. Ensure backplate is oriented
front side forward.
Note: Be sure backplate is
oriented front side forward and markings are
visible.
If mounting to an uneven surface, apply
appropriate sealant around the backplate to
supplement rubber seal. Align holes in escutcheon
(5) with cartridges and slide escutcheon (5) onto
backplate. Secure escutcheon by threading trim
nut (6) onto diverter sleeve. Do not overtighten.
Slide diverter trim sleeve (7) over trim nut and
secure into position with set screw (8).
For
thick wall installation, an optional extension
kit is available to accommodate up to 1" of
additional wall thickness. Order RP91022
▲
&
RP92548.
B.
4
2
3
5
6
5
3
Trim Installation
75 Series Installation
D.
2
Adjust temperature limit stop
Turn on water supplies; LET WATER RUN AT
FULL HOT TO ENSURE WATER IS AS HOT
AS POSSIBLE. Place a thermometer in a plastic
tumbler and hold tumbler in water stream.
Aligning the splines, place temperature handle
(1) onto end of cartridge stem (2). Rotate handle
until desired maximum temperature is achieved
(not more than 120° or lower, as mandated by
local plumbing code).
Remove temperature handle (1). Replace handle
onto cartridge stem with handle limit stop (4)
against volume handle limit stop (3), as shown.
Secure temperature handle with set screw (5)
and press button cover (6) into hole.
1
4
Installation and Adjustment of the Temperature Handle. Failure to do so
may cause injury. Please complete the following steps carefully.
3
Volume Handle Installation
Slide volume control handle (9) over cartridge,
aligning at surfaces inside handle with at
surfaces on side of cartridge. Handle lever
should point downward (6 o'clock) in the off
position. Secure handle with set screw (10) and
press button (11) cover into hole.
9
10
11
C.
5
6
7
8