Instruction Manual

109508 Rev. B
3
1
Cartridge Installation
Rotate the cartridge (1) so the H (2) is on the hot
inlet side of the valve.
Insert cartridge into valve
body as shown. Make sure the cartridge tubes
and O-rings (3) are properly seated in holes at
the base of the body. Ensure the keys on the
body are fully engaged with the slots in the
body (4).
For back to back or reverse installations
(hot on right and cold on left): Rotate cartridge
(1) so the word “UP” (2) appears on the bottom.
Install the cartridge making sure that the keys are
fully engaged with the slots in the brass body (see
step B). Slide bonnet nut (3) over the cartridge and
thread onto the body. Hand tighten securely.
Back to back Installation
Normal Installation
(changes not required)
Reverse
Installation
Cold
Hot
1
3
2
B.
1
4
4
3
Slide bonnet nut (1) over the cartridge and
thread onto the body. Hand tighten securely.
C.
1
Turn o󰀨 water supplies. Remove bonnet nut
(1) and test cap (2) from the body. If this is not
a thin wall mounting, the entire plasterguard (3)
may be removed. If screen (4) is in place, remove
before installing cartridge.
A.
1
2
3
4
2