Operation Manual

13
11 Technical Data
Display Unit 62 mm/50 mm/17 mm (L/W/H)
Sensor 81.5 mm/43 mm/45.5 mm (L/W/H)
Installed position horizontal
Flow range 10 to 100 l/h
Flow deviation +/– max. 5 %
Operating pressure max. 8 bar
Pressure loss up to 100 l/h fl ow < 0.2 bar
Water intake temperature C to 30°C
Ambient temperature operation/storage/transport 0°C to 60°C
Battery button cell 3VDC, Type CR2032
Degree of protection Display Unit (only when wall-mounted) IPX 4
Degree of protection Sensor IPX 8
Cable length max. 1.5 m
Inlet connection 1 x G 3/8" union nut
Outlet connection 1 x G 3/8"
12 Order number
BRITA
®
FlowMeter 10100A 298900