User guide
27
Maintenance - cont.
Adjusting the Temperature
The shower valve has been factory set
with equal (balanced) hot and cold water
supply pressures with the hot water
supply at 65˚C.
If your operating conditions are different
from those above, the outlet water
temperature may differ from the factory
setting.
If required the shower valve can be re-
calibrated to suit your own temperature
requirements.
Set the temperature control lever to
maximum and check the temperature
of the water with a thermometer. If the
temperature is not correct, re-calibrate
the shower valve:
1. Turn the lever anti-clockwise to the
maximum temperature position.
2. Remove the lever: remove the plastic
cap, loosen the grub screw using the
hexagonal key (10) and carefully pull the
lever off.
3. Using the hexagonal key, turn the
temperature adjusting screw to alter the
temperature.
• Turn clockwise for a cooler temperature
• Turn anti-clockwise for a warmer
temperature
Note: This will be the maximum
temperature setting, it is recommended
that the temperature is set no higher than
43˚C.
4. Once the correct temperature is
achieved, re-attach the lever and close
the valve. Ensure the stop on the lever is
in the correct position (vertically down),
allowing the valve to turn on anti-
clockwise.
5. Tighten the grub screw to lock the lever
in place and push fit the plastic cap.
C
H
Warmer
Cooler
Temperature
adjusting screw