User guide
6
Installation Requirements
This shower valve must be installed 
in compliance with current water 
regulations. If you have any doubts about 
the water regulation requirements contact 
your local water services provider or use 
the services of a professional plumber.
This shower valve is suitable for use with 
the following water supply systems:
• Gravity Fed Hot and Cold  
(pressure balanced)
• Gravity Fed Hot and Mains Cold 
(differential pressure - see Specification 
section on page 12)
• Instantaneous water heater  
(combination boiler)
• Unvented System
• Pumped System
Gravity Fed Hot and Cold 
Gravity Fed Hot and Mains Cold 
cold mains supply
cold mains supply
Important: If you install this shower 
valve with a gravity fed system, there must 
be a minimum head (vertical distance) 
from the underside of the cold water 
storage tank to the showerhead position 
of at least 1 metre.
Note: Pumped system (with Essex 
flange) If you install this shower valve to 
a pumped gravity fed system where the 
minimum head (vertical distance) from 
the underside of the cold water storage 
tank to the top of the hot water cylinder 
is less than 1 metre we recommend an 
Essex flange is used as shown.
Flushing Pipe-work
Important: Before connecting the 
shower valve (see ‘Installation’ on pages 
16-17), supply pipe-work must be flushed 
to clear debris before connecting the 
shower valve. Debris will reduce the 
performance and life of the shower.
1m min.
1m 
min.