Adjusting the Temperature
Adjusting the Temperature
The shower valve has been factory set
with equal (balanced) hot and cold water
supply pressures with the hot water
supply at 65˚C.
If your operating conditions are different
from those above, the outlet water
temperature may differ from the factory
setting.
If required the shower valve can be re-
calibrated to suit your own temperature
requirements.
Turn the temperature control until
it reaches the stop and check the
temperature of the water with a
thermometer. If the temperature is not
correct, re-calibrate the shower valve:
1. Remove the temperature control cover,
undo the screw and carefully remove the
handle but do not remove the plastic stop.
2. Turn the spline clockwise to decrease
the temperature and anti-clockwise to
increase the temperature. Check the
temperature and adjust until you achieve
the required temperature.
3. Replace the handle ensuring the ‘stop
pin’ inside the handle is up against the
plastic stop.
4. To nish, reinsert the screw and
push on the cover (will only fi t on in one
position).
Screw
Cover
Handle
Plastic stop
(Do not remove)
Spline