User guide

16
b) Screw fi xing plate to the wall
Using suitable screws for the wall type
secure the wall mount fi xing plate to the
wall. There is a hole in each corner of the
xing plate for the fi xings.
Installation - New First Fix
If this is a new installation follow First &
Second fi x installation.
If replacing an existing shower valve
proceed to Retro-fi t installation on page
19.
Before Installation
Flush through the pipework to ensure
removal of debris. Turn off the mains
water supply and close any isolating
valves.
1. Position fi xing backplate
Identify the required position of the
shower valve, where the wall mount fi xing
plate will be installed.
Mark a 230mm x 50mm rectangle on the
wall surface.
Warning: Please check for any hidden
electrical wires, cables or water supply
pipes before drilling / cutting into the wall.
2. Prepare water supply pipes
The centres of the hot and cold water
supply pipes should be 150mm apart, with
a suffi cent amount of pipework protruding
through the wall.
3. Fit wall mount fi xing plate
The wall mount fi xing plate has two
methods of fi xing.
a) Tighten fi xing lugs
Tighten the two screws in the middle of
the fi xing plate and the two either side of
the inlets, Tightening these screws will
secure the lugs against the inside of the
wall surface.
Important: Water supplies to the mixer
must be with hot on the left and cold on
the right when viewed from the front.
230mm
230mm
50mm
50mm
Lug
Screw
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk