User Guide

WET-AREA CLOTH HEATERS & INSULATORS
Certified to UL safety standards
Specications:
Maximum Temperature and Watt Densities:
- For vented
1
metal vessels: 212°F (100°C) | 0.80 W/in
2
(0.12 W/cm
2
)
- For sealed
2
metal vessels: 130°F (54°C) | 0.45 W/in
2
(0.07 W/cm
2
)
- For vented
1
poly vessels: 160°F (71°C) | 0.45 W/in
2
(0.07 W/cm
2
)
- For sealed
2
poly vessels: 100°F (37°C) | 0.25 W/in
2
(0.04 W/cm
2
)
1
Vessel has access/opening to atmosphere. Examples include open drums, IBCs,
hoppers, and containers
2
Vessel is sealed but has a pressure release device. Examples include valves, pipes,
actuators, pumps, and sealed containers
Voltage: 120 to 240 VAC
Amperage: 12A maximum for ETL approval
Outside Material: Extra-durable polyester cloth
Insulation Material: Mold/mildew resistant melamine
Insulation Thickness: Standard 0.5 in (130 mm) or 1.0 in (260 mm) thick.
Other insulation thicknesses available upon request
Ingress Protection Rating: IP54
Water
Resistant
Ordering Information:
Wide Range of Design Options:
Heating jacket or insulator-only (no ETL)
Custom shapes, sizes, and configurations
Holes and cut-outs
Choice of lead lengths and terminations
Choice of closure type
Built-in thermostat control, integrated digital temperature
controller, or connect to external control
High-limit thermostats
Straps with buckles
Hook & loop
Grommets & lace
Common closure options:
Belts with
“D” rings
When ordering, the following information is required:
Note: For designs with cut-outs, holes, or multi diameters, a
dimensional drawing is required.
Length
Width or Internal Diameter
Voltage
Closure Type
Lead Length
Termination Type
Custom Options
Plug-and-play options: Built-in
thermostat control or integrated
digital temperature controller
PIPES
VALVES
PUMPS
VESSELS
& MORE
HEAT & INSULATE
Your Heating Specialist since 1949
YES
WE HEAT
THAT!