5.3 HIGH TEMPERATURE ALARM DISPLAY – If the measured temperature goes up by more than the figure in
the ALARM HI screen, the alarm will sound immediately and “+T” will be displayed. Press OK to silence the
alarm for 30 minutes.
If the high temperature problem rectifies itself the “+T” remains on the display to show this has happened. Press
OK to clear the indicator. Check the incubator is not (and has not been) in direct sunlight or too near a heat
source such as a room heater. It is advisable to candle eggs a number of times after this event to check for losses.
5.4 LOW TEMPERATURE ALARM DISPLAY – If the measured temperature goes down by more than the figure
in the ALARM LO screen, after 30 minutes “-T” will be displayed and the alarm will sound. Press OK to silence
the alarm for 30 minutes.
If the low temperature problem rectifies itself the “-T” remains on the display to show this has happened. Press
OK to clear the indicator. Check the incubator is not (and has not been) in a cold draught or that the room
temperature has dropped significantly. It is advisable to candle eggs a number of times after this event to check
for losses.
5.5 TURN SYSTEM PAUSE DISPLAY. (Please refer to section 9 for details)
TO PREVENT THE RISK OF POSSIBLE INJURY OR DAMAGE TO THE MECHANISM NEVER
INITIATE A TURN WITH THE DOOR OPEN.
DO NOT OPEN THE DOOR WHILE THE SHELVES ARE MOVING. AN ALARM SOUNDS AT THE
START OF EACH TURN TO WARN THE OPERATOR. THE SHELVES MAY BE STOPPED BY
PRESSING ANY BUTTON ONCE.
A turn may be initiated at any time by pressing buttons OK and - . The shelves may then be stopped in any
position (e.g. level to allow removal of the trays) by pressing any button. The turn is left in one of two states
depending on whether automatic turning is set on or off:-
If automatic turning is set to on (1) in the Main Menu the current turn is "paused". It may be restarted again by
pressing any button. If it is not restarted within 30 minutes an alarm sounds to remind the operator. This function
is useful for inspecting eggs.
If automatic turning is set to off (0) in the Main Menu then the current turn is cancelled. The shelves remain
fixed in their current position. This function is useful for using the incubator as a hatcher.
T 39.8C
H 45%+T/
T*32.1C
H 45%-T/
T*37.5C
PAUSE