Problem Possible SourceSolution
Engine problems. Service engine.
No AC output from Main Breaker in off position. Place breaker in the on position.
generator.
Main Breaker tripping from Reduce the load on the generator.
overload.
Main Breaker tripping from a Find the short in the system and
short circuit. correct.
Generator problem. Contact your local dealer or dis-
tributor for assistance.
Low output Overloading generator. Reduce the load on the generator.
(Frequency)
Faulty capacitor. Replace capacitor.
Generator problem. Contact your local dealer or
distributor forassistance.
High output Faulty capacitor. Replace capacitor.
(Frequency)
Generator problem. Contact your local dealer or dis-
tributor for assistance.
Generator stops No Fuel. Check fuel source.
suddenly.
Low oil pressure shutdown. Check oil level and pressure.
(LED will be steady Red)
Overcrank shutdown. Place the controller in the off
(LED Will be steady Red) position for 30 seconds and return
to desired position. If the auto-
matic shut down occurs again,
check the generator system and
controller.
Blown Controller Fuse Replace fuse. If it blows again,
inspect controller for faults.
Engine Problems. Service engine.