INDUSTRIAL PORTABLE INSTALLATION AND OPERATORS MANUAL WC10000VE SHOWN WITH DOLLY KIT INSTALLED WINCO INC. 225 S. CORDOVA AVE. LECENTER, MN 56057 507-357-6821 SERVICE DEPT.
SAVE THESE INSTRUCTIONS COPY YOUR MODEL AND SERIAL NUMBER HERE This manual contains important instructions that should be followed during installation and maintenance of the generator and battery. Read and understand all instructions in the manual before starting and operating the generator set. No other WINCO generator has the same serial number as yours. It is important that you record the number and other vital information here.
SAFETY INFORMATION 2. FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and/or fire. This engine generator set has been designed and manufactured to allow safe, reliable performance. Poor maintenance, improper or careless use can result in potentially deadly hazards; from electrical shock, exhaust gas asphyxiation, or fire. Please read all safety instructions carefully before installation or use. Keep these instructions handy for future reference.
properly engineered. The use of these 3rd party enclosures is acceptable as long as they have been certified and meet current code. e. Always avoid hot mufflers, exhaust manifolds, and engine parts. They can cause severe burns instantly. f. The use of the engine-generator set must comply with all national, state, and local codes. DO NOT attempt to operate at 50 cycles. These units are designed and governed to operate at 60 cycles only.
Failure to maintain the engine oil at the proper level will result in serious engine damage. Split-Phase (SP) type. The chart below shows the approximate current required to start and run various types and sizes of 120 volt 60 cycle electric motors under average load conditions. HP AMPS RUNNING When you unpack your new engine-generator set be sure to remove all the information sheets and manuals from the carton. STARTING AMPS SP CAP RI 1/6 3.2 16 to 22 6 to 13 5 to 8 1/4 4.
burning cigarettes away from the battery. Ventilate the area when charging or using the battery in an enclosed space. Lead acid batteries contain sulfuric acid, which causes severe burns. If acid contacts eyes, skin or clothing, flush well with water. For contact with eyes, get immediate medical attention. The use of fuel additives, such as STA-BIL, or an equivalent will minimize the formation of fuel gum deposits.
The automatic Conserver® control consists of a solid state module mounted in the generator receptacle box, a switch, resistor and an electromagnet mounted on the engine near the throttle lever. The automatic Conserver® control is only offered as a factory installed feature. It is not available for field installation. BASIC OPERATION MANUAL STARTING Refer to the engine manual for additional starting, operating, and stopping instructions. 1. 2. 3. 4.
loaded, and as a result the speed drops slightly. This slight decrease in speed, together with the voltage drop within the generator itself, results in a slightly lower voltage when the generator is loaded to its full capacity than when running no load. The slight variation in speed also affects the frequency of the output current. This frequency variation has no appreciable effect in the operation of motors, lights and most appliances.
the generator receptacles. Before plugging in all the tools and cord sets, recheck the rating of the generator set. Be sure it can handle the intended load and is compatible with the voltage, phase, and current ratings. ‘Hard Wiring’ this unit directly into a temporary construction site electrical system is NOT A SIMPLE DO-IT-YOURSELF JOB. For your safety all wiring must be done by a qualified electrician and conform to the National Electric Code and comply with all state and local codes and regulations.
installed by a licensed electrician according to all applicable codes. The electrician will move the critical circuits to be powered during the outage to the emergency panel. Keep in mind only a limited amount of amperage is available from the generator set. Some circuit breakers may still have to be turned off to prevent an overload on the generator during the initial start up. See the nameplate on your generator for the amperage capabilities of your unit. c.
gerous to the operator and destructive to the equipment. TROUBLESHOOTING HINTS CLEANING PROBLEM (SYMPTOMS) POSSIBLE Remove dirt and debris with a cloth or brush. DO NOT use high pressure spray to clean either the engine or the generator. This high pressure spray could contaminate the fuel system and the generator components. 1. Keep the air inlet screen on both the engine and generator free of any dirt or debris to insure proper cooling.
24 MONTH LIMITED WARRANTY WINCO, Incorporated warrants to the original purchaser for 24 months that goods manufactured or supplied by it will be free from defects in workmanship and material, provided such goods are installed, operated and maintained in accordance with WINCO written instructions. WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the product.