Specifications

2LOCKED FOR PRINTING – SELECT SECT. NEEDED >
57
Fig. 51
Solenoid Test
The starter solenoid is a normally open, electrically
activated switch. When the key switch is turned to
the START position, the switch closes, allowing
battery current to flow to the starter motor and crank
the engine.
1. The solenoid may be tested while mounted on
engine. A jumper test lead (1) is required for this
test.
2. Remove POSITIVE battery cable from battery.
Remove battery cable from stud terminal on
solenoid.
3. Disconnect YELLOW wire from tab terminal on
solenoid.
4. Key switch must be in OFF position.
5. Insert RED test lead into V receptacle in meter.
6. Insert BLACK test lead into COM receptacle in
meter.
7. Rotate meter selector to +
))))) (DIODE TEST)
position.
8. Attach one meter test lead to each stud terminal
on solenoid (2, 3), Fig. 52.
9. Attach one end of jumper lead to POSITIVE
terminal on battery (5).
10. Touch jumper wire to tab terminal (4) on
solenoid.
a. An audible CLICK should be heard as the
solenoid switch closes.
b. Meter should make a CONTINUOUS TONE
(indicates continuity).
+
Fig. 52
For Briggs & Stratton Discount Parts Call 606-678-9623 or 606-561-4983
www.mymowerparts.com