Specification Sheet

12kW
¹
Standby Generator
Lubrication
Oil Capacity (L / qt) 1.3 / 1.37
Low Pressure Switch Included
Lubrication System Full Pressure
Oil Briggs & Stratton 5W30 Full Synthetic
Alternator Specs
Manufacturer Mecc Alte
Type Self-Excited, 4-Lead
Voltage Regulator Automatic
Insulation Class H
Peak Motor Starting kVA 37
Controller Features
Generator Sensing Single phase voltage monitoring
LCD Display Displays multi-line text and graphics
Fault Display Provides up to 39 detailed fault codes
Exercise Cycle
Six exercise length options
Default: Start and run for 16 seconds;
Abort exercise below 40° F (internal
temperature)
Engine
Engine Brand Vanguard
Engine Speed (RPM) 3600
Engine Fuel
Liquid Propane Vapor (LPV) or
Natural Gas (NG)
Engine Cylinder Configuration OHV
Number of Cylinders 2
Displacement (L / Ci) 0.627 / 38.26
Compression Ratio 8.3:1
Governor Type Electronic
Frequency Regulation +/- 0.3 Hz (0.5%)
Valves OHV with Hardened Seats
Ignition System
Fixed Timing Magnetron®
Electric Ignition
Starter Motor Rating Voltage 12 Volt
Battery Required
12 Volt, Group BCI 26 or 51,
540 CCA Minimum
High Temperature Switch Included
Dura-Bore Cast Iron
Cylinder Sleeve
Included
Engine Specifications
Operations
Fuel Consumption
2
Full Load 1/2 Load No Load
BTU / hr
NG - 172,000
LPV - 209,000
NG - 117,000
LPV - 155,000
NG - 66,000
LPV - 57,000
ft
3
/ hr
NG - 171.6
LPV - 83.3
NG - 116.9
LPV - 61.8
NG - 66
LPV - 22.6
m
3
/ hr
NG - 4.87
LPV - 2.37
NG - 3.31
LPV - 1.76
NG - 1.87
LPV - 0.65
g
/ hr LPV - 2.26 LPV - 1.68 LPV - 0.62
Sound Rating At 7 Meters
Low Idle Mode 64 dBA
4
No Load 69 dBA
4
3
Unlike some other standby generator manufacturers, our warranty covers parts, labor AND travel
for the full length of the warranty with no start-up costs!
1
This generator is certified in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C22.2 No. 100-14 (motors and generators).
2
Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary
depending on these factors.
3
See operator’s manual or BRIGGSandSTRATTON.com for complete warranty details.
4
Lowest no-load measurement per ISO 3744. Sound level measurement at other locations around generator may be different depending upon installation configuration.