Installation Guide

13
Anchoring and Wind Rating
Concrete Anchoring of Unit to Poured or
Existing Slab
To achieve the listed wind rating, the generator must be
installed in strict compliance with this installation manual.
The product components must be of the material specified
and all screws must be installed in accordance with the
applicable provisions and the anchor manufacturer’s
published installation instructions.
The concrete slab/pad must meet the requirements below
and the generator must be anchored with the anchors
ofAnchor Types1 or 2.
Anchor Types
1. Qty (4) 3/8” SS ITW RED HEAD LDT, Anchor embedded
2 ½” (63.5mm) in 3000 psi concrete. 3” (76.2mm) from
the edge minimum, 6” (152.4mm) spacing minimum.
2. Qty (4) 3/8” SS Powers/Dewalt Power Stud +SD2
Anchor embedded 2 ½” (63.5mm) in 3000 psi concrete.
3” (76.2mm) from the edge minimum, 6” (152.4mm)
spacing minimum.
There are four 7/16” hole locations (A) in the base of the
generator in which to anchor the unit.
Concrete Slab/Pad Types
PAD DIMENSIONSWIND
RATING
MPH
PAD
MODEL
Width Length Thickness
CONCRETE
SPEC
Up to 140 Pre-cast
Pad
(contact
dealer)
29in
(736.6mm)
32in
(812.8mm)
3in
(76.2mm)
3000 PSI
140 to 175 Pre-cast
Pad
(contact
dealer)
29in
(736.6mm)
32in
(812.8mm)
4in
(101.6mm)
3000 PSI
140 to 175 Poured 30in
(762mm)
32in
(812.8mm)
5in
(127.6mm)
3000 PSI
These items are available at your local service dealer.
NOTICE Unless mandated by local or state codes, or
required to achieve wind rating, a concrete slab/pad is not
required
Not for