Dimensions Guide
12kW
¹
 Standby Generator
Lubrication
Oil Capacity (oz) 48
Lubrication System Full Pressure
Recommended Oil 5W30 Full Synthetic
Alternator Specs
Manufacturer Mecc Alte
Type Self-Excited, Rotation Field
Voltage Regulator Brushless
Insulation Class H
Controller Features
Hour Meter Yes
LED Digital Display Yes
Fault Code Display Yes
Weekly Exerciser Yes
Low Oil Pressure Shutdown Yes
High Temperature Shutdown Yes
Engine
Engine Brand Vanguard®
Engine Speed (RPM) 3600
Engine Fuel
Liquid Propane Vapor (LPV) or 
Natural Gas (NG)
Engine Cylinder Configuration OHV
Number of Cylinders 2
Displacement (cc) 627
Compression Ratio 8.3:1
Governor Type Electronic
Frequency Regulation +/- 1 Hz
Valves OHV with Hardened Seats
Ignition System
Fixed Timing Magnetron®  
Electric Ignition 
Starter Motor Rating Voltage 12 Volt
Battery Required
12 Volt, Group BCI 26 or 51, 
540 CCA Minimum
Operations
Engine Specifications
Fuel Consumption
2
Full Load 1/2 Load No Load
BTU/hr
NG - 172,000
LPV - 209,000
NG - 117,000
LPV - 155,000
NG - 66,000
LPV - 57,000
ft
3
/hr
NG - 171.6
LPV - 83.3
NG - 116.9
LPV - 61.8
NG - 66
LPV - 22.6
m
3
/hr
NG - 4.87
LPV - 2.37
NG - 3.31
LPV - 1.76
NG - 1.87
LPV - 0.65
Sound Rating At 7 Meters
69 dBA
4
3
Unlike other standby generator manufacturers,  
our warranty covers parts, labor AND travel for the 
full length of the warranty with no start-up costs!
1
  This generator is certified in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C22.2 No. 100-14 (motors and generators).
2
 Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary 
depending on these factors.
3
 See operator’s manual or BRIGGSandSTRATTON.com for complete warranty details.
4
 Lowest no-load measurement per ISO 3744. Sound level measurement at other locations around generator may be different depending upon installation configuration.