Installation & Operating Guide
19
Sensor Error 3
0 = No Error
1 = Temperature Error (>135°C)
7
6
1
N/A
N/A
0
1
N/A
N/A
Sensor Error 2
0 = No Error
1 = MMIC Error
7
5
1
N/A
N/A
0
1
N/A
N/A
Sensor Error 1
0 = No Error
1 = Voltage Error
7
4
1
N/A
N/A
0
1
N/A
N/A
Not used
7
2
2
N/A
N/A
N/A
N/A
N/A
N/A
Identification Flag
0 = BS-9000
1 = 77GHz Radar
7
1
1
N/A
N/A
0
1
N/A
N/A
Detection Flag
0 = Valid detection
1 = No detection
7
0
1
0
1
0
1
0x00
0x01
5.8
Sensor Start-up Messages
Each sensor will transmit various messages to the host upon power up. These messages may
be used by the host to confirm that the particular sensor in the network has correctly started
and is operational.
The transmission of the start-up messages is sufficient to verify that the sensor is operational.
Start-up time (from power-on to completion of start-up messages) is detailed in section 9. The
content of the start-up message has no functional use for the normal operation of the sensor
and provide no information to the user.
The table below details start-up message vs sensor Base ID
Sensor ID Number
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
Base ID
0x310
0x320
0x330
0x340
0x350
0x360
0x370
0x380
0x390
Start-up
Message 1
0x700
0x701
0x702
0x703
0x704
0x705
0x706
0x707
0x708