Installation manual
TM
Network Management Manual
580-00511, rev B 32 of 34
8.4 SNMP MIB Objects
Supported MIB-2 Groups
Name
OID
system
1.3.6.1.2.1.1
interfaces
1.3.6.1.4.1.2
at
1.3.6.1.4.1.3
ip
1.3.6.1.4.1.4
icmp
1.3.6.1.4.1.5
tcp
1.3.6.1.4.1.6
udp
1.3.6.1.4.1.7
egp
1.3.6.1.4.1.8
transmission
1.3.6.1.4.1.10
snmp
1.3.6.1.4.1.11
Interfaces: MIB-2 interface table is always populated with the following five
entries. 1 = Loop-back, 2 = Management port 3 = Copper port, 4 = Fiber port and
5 = Radio port
BridgeWave Enterprise MIB Objects
Name
OID
Description
brwaveUnitSn
1.3.6.1.4.1.6080.2.1 Units serial number
brwaveUnitModel
1.3.6.1.4.1.6080.2.2
Unit Model Number
brwaveTrapCount
1.3.6.1.4.1.6080.2.6
Traps generated by a given unit
brwaveRadioTxBand
1.3.6.1.4.1.6080.3.1.2.1
Radio’s transmitting frequency
band
brwaveRadioFactoryRate
1.3.6.1.4.1.6080.3.1.2.3
Radio’s operating data rate
brwaveRadioInVoltage
1.3.6.1.4.1.6080.3.1.3.1
Radio’s Input voltage
brwaveRadioUnit
Temperature
1.3.6.1.4.1.6080.3.1.3.2
Radio’s internal unit temperature
brRadioTxTemperature
1.3.6.1.4.1.6080.3.1.3.3
Radio’s transmitter temperature
brwaveRadioRSL
1.3.6.1.4.1.6080.3.1.3.4
Receive Signal Level
brwaveRadioRSLVoltage
1.3.6.1.4.1.6080.3.1.3.5
Corresponding Voltage of RSL
BridgeWave Enterprise MIB Traps
Unit Temp
Abnormal
Internal Temp outside of –20 to +75 degrees Celsius range
Unit Temp Normal Internal Temp restored to normal range
Transmitter Temp
Abnormal
Transmitter outside of –20 to +75 degrees Celsius range
Transmitter Temp
Normal
Transmitter Temp restored to normal range
RSL Major RSL drops below critical level -64dBm <-54dBm Depending on AR