Installation manual
TM
Network Management Manual
580-00511, rev B 16 of 34
4.1 AdaptRate (AR products only)
The operation mode of the AR60(X) and AR80 product can be set to automatically
switch between 1000 and 100Mbps depending on the receive level of the radio. This
is the default setting for the radio, but it is also possible to force an AR radio to be
fixed to 1000 or 100Mbps. This field is present only for AR60(X) and AR80 models.
4.2 Installation auto-calibration
Installation auto-calibration is enabled as the factory default. With this setting, the
radio will perform an auto-calibration every time the radio is power cycled with the
fiber connection down, followed by the fiber connection changing from down to up.
After the physical installation and alignment procedure is complete, this should
normally be changed to disabled.
4.3 Fiber Interface (GigE)
The fiber interface for the radio units (whether operating in 100 Mbps or 1000 Mbps
mode over the air) is 1000Base-SX (850nm multi-mode). The only setting that can be
changed is to enable or disable auto-negotiation. The units are set with auto-
negotiation enabled as the factory default. It is important that the BridgeWave radio
and the customer network equipment interfaces be configured identically; both
interfaces should be configured to auto-negotiate or else both should be configured to
not auto-negotiate.
Note: When auto-negotiation is disabled on the fiber interface, then flow-control will
also be disabled. If the radio and the network equipment are configured differently, it
is likely that a connection will not be established over the fiber.
4.4 Management Agent
This section provides information about the management agent MAC address and
allows for the configuration of its IP address, subnet mask and default gateway. These
values are normally provided by the network administrator.
IP address: Allows for the configuration of the IP address for the
management agent. The factory default for the high-band
radio is 192.168.0.2 and for the low-band radio is
192.168.0.1.
DHCP: Checking this box enables the unit to receive an IP address,
subnet mask and default gateway from the network’s