Installation manual
TM
Network Management Manual
580-00511, rev B 14 of 34
4. Setup Page
On the Setup page you can view or configure the radio interface, fiber network
interface and management agent settings. The page is split into two separate parts
with the left site of the page allowing for changes to the configuration and the right
side of the page displaying the currently effective values. Current active values are
displayed in red once new values have been submitted, pending a system restart. All
values will be displayed in black after the restart has completed. The following items
can be configured on the Setup page:
• Adaptive rate setup: select AdaptRate, 1000 or 100Mbps (Available only for
AR60,AR60X , AR80)
• Installation auto-calibration behavior
• Fiber interface auto-negotiation and flow-control parameters
• Management agent IP configuration
• Enable or disable Link State Propagation.
• Enable or disable access to the management agent through each of the
network interfaces, (at least one must be selected).