Datasheet
AR/GE/FE/U80/80XInstallationManual
34 58000519rev.D
Apendix A Troubleshootin g
Thefollowingtableprovidesasummaryofpossibleproblemsyoumightencounterwhileinstallinga
BridgeWave80GHzlink,alongwithpossiblecausesandtheirsolutions.
Extensivetroubleshootingsupportandknowledgebasearticlesare
availableattheBridgeWaveeSupportknowledgebaseonlineat:
http://bridgewave.com/support/kbrma.htm
ContactBridgeWavesupporttoobtainaloginaccount.
TableA1:Troubleshooting
Problem PossibleCause Resolution
Nopowertoradio Wrongpolarityof supplyvoltage UseaDVMtodeterminethe
polarityandvoltageontheDC
cable.
(SeeSection3.7.2)
Thesupplyvoltagemeasuredat
theradio(whenconnected)is
below15VDC
Thecablerunistoolongor the
cablegaugeistoosmall.
Shortenthelengthofthecable
oruselargergaugecable.
(Seesection3.7.2)
Fiberlightlitatradiobutnoton
networkequipment
Fiberconnectornotinserted
properly
Checkfiberconnectionsatradio
andatnetworkequipment.
Inconsistentfiberport
configurationbetweenradiounit
andconnectedswitchorrouter.
Verifytheconfigurationofthe
networkequipment.Bothports
musteitherbesettoauto
negotiateoreachmustbesetto
notautonegotiatewithflow
controldisabled.
Oneorbothofthefibershave
beendamaged
Usealoopbackconnectorat
theradiotoverifytheradiois
OK,repeatatthenetworking
equipment.Visuallyinspectthe
fibercable.
RadiolinkisdownANDLSP
modeenabled.
Operationnormal.
CheckRFstatusofbothradios
andLSPoptionofbothradios
NMSSetuptab.
Checkforraineventorother
obstructioninRFpath,orradio
isoutofalignment.
RSLvoltagelowerthen
expected
Incorrectcalculationoflink
distance
Verifythatthecalculationtool
usedandtheGPSusedboth
havethesameannotation
system(degreehoursminutes
secondsordegreewitha
decimalvalue)