Datasheet

AR/GE/FE/U80/80XInstallationManual
6 58000519rev.D
cables.Astandardcrimping/splicingtool(not provided)isrequiredtoterminatethepower
connectorsontoa1412gaugecablerequiredforusewiththe80GHz.
On theradioendnoconnectorsarerequired;simplyscrewterminalstoappropriatepolarity.TheDC
powercableshouldbefedint otheconnectoronthecasingfirstandthenthegreenconnector
attachedtotherad ioaft ermakingastrainreliefcoilaroundtheelect ronichousing.
Figure2.61: (Left)14gaugeDCpowercableterminated toradioend.(Right)DC14gaugecablefromthepower
supplyend.
2.7 Grounding&Lightning
Propergroundingoftheoutdoorequipmentreduces
electromagneticinterference,provideslightningprotection,and
protectsagainstelectricaldischarge.
Usingimpropertechniquesinlightningpronegeographicareas
mayposeadangertolocalpersonnel.
Thesourceandconnectionpointsforthebuildingtoearthground
inthevicinityoftheantennalocationshouldbedetermined.
Inadditiontogroundingtheequipment, BridgeWavestronglyrecommends,andlocal building
codesmayrequire,theDCelectricalca bletobeprotectedfromelectr icalsurgesbyasurge
suppressor.Thesurgesuppressormustbeinstalledat thepointwheretheDCelectricalcables
exit/e nterthebuilding.