Installation Guide

repress and hold the heater icon for 10 seconds again, then the ember bed will also flash
indicang the heater funcon is unlocked and to recover the original states which you have
set.(Note: This can't be set with the remote control).
TIMER
The TIMER has adjustable seng at range from 1 hours to 8 hours and OFF. As shown the
following: 1h-2h-3h-4h-5h-6h-7h-8h-OFF. Once you have set the mer, and the mer is up, it
will close all the funcons and enter standby mode. In this mode, you should touch the power
icon to restart the appliance.
INCREASE/DECREASE BUTTON
The Level Selecon buon is used to adjust the heat seng and the brightness of flame. See
relevant secon for more details.
BATTERIES REPLACEMENT
NOTE:
·Do not mix old and new baeries.
·Do not mix alkaine, standard (carbon zinc), or
rechargable (nicad, nimh, etc.) baeries.
·Do not ingest baeries.
CAUTION:
·Always purchase the correct size and grade of baery most suitable for the intended use.
·Replace all baeries of a set at the same me.
·Clean the baery contacts and also those of the device prior to baery installaon.
·Ensure the baeries are installed correctly with regard to polarity (+ and -).
·Remove baeries from equipment which is not to be used for an extended period of me.
·Remove used baeries promptly.
TROUBLESHOOTING
8
Fault code Fault Cause Soluon
E1 The heater overheang
E2 NTC is defecve. Call aer-sales service.
Call aer-sales service.
The heater not working.
If the vents are dirty or clogged. Unplug the power,
clean the dust and debris of the vent area. Wait for 5
minutes, plug in and turn on the heater. If the heater
sll don't work, please call aer-sales service.
E3
POWER
The power buon turns the fireplace on & off. When the fireplace is off, pressing the power
buon once will switch on the fireplace. Once on, if the fireplace display is not illuminated
pressing the power buon will light up the display. If the power buon is pressed again within
10 seconds it will turn off the fireplace. If the display is already illuminated then only one press
of the power buon is needed to turn off the fireplace.
The fireplace has a built-in memory funcon and when turned back on it starts at the last used
sengs (except mer). If the fireplace is disconnected from the main power source, it reverts
to the default sengs.
FLAME
This buon is used to turn flames ON, to alter the flame color and to turn flames OFF. Press
the Flame buon mulple mes to cycle through 7 color opons (L8, L7, L6, L5, L4, L3,L2),
color rotaon opon (L1) and flames OFF.
While L8, L7…or L2 is displayed, press the Level Selecon buon to change the brightness of
the flames from the available opons: 4- brightest, 3-brighter , 2-bright , 1-darkest .
HEATER
The Heater Buon turns the heater On & Off.
With Heat ON and set temperature displayed, press the Level Selecon buon mulple mes
to cycle through the 11 temperature sengs: 82-ON - 64- 66 - 68-70-72-74
-76-78-80 (27-ON - 18-19- 20-21 -22-23- 24-25-26).
Temperature unit convert funcon: When the heater is on, press and hold the Power Buon
for 5seconds, current temperature unit display will flash 3 mers and convert to another
temperature unit (Note: This can't be set with the remote control).
Lock & unlock heater funcon: press and hold the Heater Buon for 10 seconds, the ember
bed will flash, indicang that the heater funcon is locked. To unlock the heater funcon, just