Installation guide
22
APEX615n Installation Guide
APEX6152 & APEX6154 Internal Connections
Motor Connector
Front Panel – Right Side
Front Panel – Left Side
AC Input
Connector
3 Phase
Rectifier
+
–
Low Voltage
Power
Supply
Controller
for
Power
Amplifier
V Bus +
Regen Resistor
V Bus –
Phase A
Phase B
Phase C
±15V
Tach Output
Gnd / Resolver Shield
ANA
GND
LEDs
Encoder Output
Resolver
Motor Ground
Shield
L1
L2
Earth
L3
Earth
3 – Phase
Power
Amplifier
Control L1
Control L2
DC-to-DC
Converter
6000
Controller
Iso +5V
+15V
–15V
Iso Ground
Triggers
Programmable I/O
Iso Gnd
+5V (isolated)
COM 1
COM 2
Limits
You must connect AC power to both L1/L2/L3 and Control L1/Control L2 (or to both L1/L2 and
Control L1/Control L2 on the APEX6151. The next drawing shows a simple way to do this.
L1
L2
L3
Earth
Earth
Control L1
Control L2
AC Power
Source
Disconnecting
Means
Disconnecting
Means
AC Input
Connector
Using insulated jumper wires:
• Connect L1 to Control L1
• Connect L2 to Control L2
L1
L2
Earth
Earth
Earth
Control L1
Control L2
AC Power
Source
AC Input
Connector
APEX6152 and APEX6154APEX6151
AC Connector with Jumpers Attached