User`s manual
- 55 -
Abandon End: After the system alarms for the lost object, the system shall start to save a
picture as the next comparison target. To continue the previous example, if the chosen stream
is configured as 15 fps, and this parameter is 300, then 20 seconds after the system alarms for
the lost object, the system shall save a picture as the next comparison target.
Digital Input (DI)
The DI socket allows the IP camera to receive input from an external device. The external
device should have the ability to drive voltage on the connected DI wire to the triggering voltage
level in order to notify the IP camera of any event of interest. The IP camera will then process
the event notification according to the specific event rules. Triggering voltage Level: LOW,
HIGH, Rising and Falling. Users should select the option according to the capability of their
external device.
PIR(*)
The PIR (Passive InfraRed) sensor measures infrared light radiating from objects in its field of
view. This can be used to detect a moving object, such as a person, in dimly lit areas.
Sensitivity – Adjust the sensitivity of the PIR Sensor from the drop down menu. The sensitivity
can be set from 10 - 100%; with the default sensitivity set at 50%. Higher sensitivity levels will
increase the range of the PIR Sensor. When the sensitivity level is set to 100%, the PIR