We recommend asking one of the Authorized Service Centers for a periodic maintenance contract
which includes:
cleaning the condenser
cleaning the filter located on the water supply solenoid valve
checking the charge of coolant gas
checking the operating cycle
sanitizing the appliance
10 PERIODS AT A STANDSTILL
If you do not intend to use the appliance for a certain period of time, proceed as follows:
switch off the electric power source by means of the switch (7 in Fig. 5), and remove the plug of the
appliance from its socket
shut off the water supply by turning off the water supply tap (8 in Fig. 5)
empty the inner basin, removing the flap panel and extracting the ice-cube slide and the overflow pipe
(Fig. 10)
empty out the pump body blowing compressed air into the pipe that supplies water to the sprayer
bank (Fig. 15)
clean water supply solenoid valve filter as described in chapter 9.1
clean air condenser filter (air-cooled models) as described in chapter 9.2