PS150 Slimline and PS400 Slimline Digital Receiving Scale User Instructions AWT 35-100029 Issue AB
Brecknell is part of Avery Weigh-Tronix. Avery Weigh-Tronix is a trademark of the Illinois Tool Works group of companies whose ultimate parent company is Illinois Tool Works Inc (“Illinois Tool Works”). Copyright © 2020 Illinois Tool Works. All rights reserved.
1 General Information and Warnings The PS150 Slimline is a 150lb Digital Receiving Scale. The PS400 Slimline is a 400lb Digital Receiving Scale. Both units can be powered with (4) AA batteries or by using the provided power supply that plugs into the side of the indicator. The scale is equipped with a movable display that can be placed on the work surface or mounted to the wall. 1.1 Specifications Capacity (LB): PS150 Slimline = 150lb x 0.1lb / 70kg x 0.05kg PS400 Slimline = 400lb x 0.2lb / 200kg x 0.
1.3 1.4 Installation 1. Remove the scale and indicator from the box. 2. Connect the power supply to the side of the indicator or install batteries. Refer to section 1.4 for information on installing batteries. Battery Installation The Digital Receiving Scale operates with (4) “AA” batteries (Alkaline preferred). The battery compartment is located on the underside of the indicator portion of the scale. Battery compartment door 1.5 1. Turn the indicator over to expose the battery compartment. 2.
1.6 1.7 Mounting the Indicator 1. Mount bracket to wall using (2) screws that are appropriate anchors for the surface being mounted to. 2. Using the grooves in the rear of the indicator, slide indicator onto mounted bracket. Routine Maintenance IMPORTANT: This equipment must be routinely checked for proper operation and calibration. Application and usage will determine the frequency of calibration required for safe operation.
PS150 Slimline and PS400 Slimline User Instructions 7
2 General Operation 2.1 Display and Function Unit of Measure Annunciator Stable Annunciator 2.2 Keypad Tare Button When pressed one time, the scale will tare (zero out) the load on the platform. Unit Button Press to change between the following units of measure: kg, lb, lb-oz. ON/OFF Button Press to turn the scale "ON" or "OFF". By default, the scale turns off automatically after 5 minutes of inactivity.
2.3 Functions 2.3.1 Power on To turn the scale on, press the ON/OFF button. The display will turn on and automatically zero the weight. This indicates that the scale is ready for use. 2.3.2 Weighing If the scale does not show zeros, verify that nothing is on the scale and press TARE to zero the scale. 1. When the display shows "0" it is ready to weigh an object. 2. Place the item to be weighed on the scale base. The weight appears on the indicator. 2.3.
2.4 Calibrating the Scale The PS150/400 Slimline can be calibrated using either kilograms or pounds, depending on the unit of measure you will be using the scale in. Before beginning the calibration procedure, be sure to have the necessary weights available.
4. Press the UNIT key to accept the calibration unit. The calibration span weight is displayed. 5. Press TARE to change the calibration span weight. Available span weights are shown below. Calibration in kilograms Calibration in pounds 10 kg 20 lb 20 kg 50 lb 30 kg 100 lb 75 kg 150 lb 100 kg 200 lb 150 kg 300 lb 200 kg 400 lb Values in bold italics (above) are for the PS400 Slimline, only. 6. With the correct span weight displayed, press UNIT to accept. The display flashes. 7.
Brecknell USA 1000 Armstrong Dr. Fairmont MN 56031 Tel:507-238-8702 Fax:507-238-8271 Email: sales@brecknellscales.com http://www.brecknellscales.com Brecknell UK Foundry Lane, Smethwick, West Midlands, England B66 2LP Tel:+44 (0) 8452 46 6717 Fax:+44 (0) 8452 46 6718 Email: sales@brecknellscales.co.uk http://www.brecknellscales.