Owner`s manual
Refrigerated cooler operation
Troubleshooting
Potential cause/remedy
Problem
- Check that SCC is set to required temperature - decrease if
required. Temperature set point must be less than the room
temperature sensed by the SCC for the cooler to operate.
- Check that outlets/zones are open to all areas that require
cooling.
- Check the return air grille is not obstructed.
- Check that the return air grille and filter are clean - clean if
required.
- Check that the SCC is set to COOL mode - press AC MODE
button to change to COOL mode if required.
- If operating in MANUAL mode check that HOME is selected
on SCC - press HOME/AWAY button if required.
- Check that doors and windows are closed.
House is not
cooling
effectively
- If it is accessible, check that power is turned on to the cooling
unit.
- Check that the SCC is set to COOL mode - press AC MODE
button to change to COOL mode if required.
- Allow 10 to 15 minutes for the system to operate then check
again.
- If the air is still not cool contact your installer or the cooling
unit manufacturer.
There is airflow
from the
outlets but it is
not cool.
- If it is accessible, check that power is turned on to the heater.
- Check that the SCC is set to COOL mode - press AC MODE
button to change to COOL mode if required.
- Check that SCC is set to required temperature - decrease if
required. Temperature set point must be less than the room
temperature sensed by the SCC for the cooler and heater fan
to operate.
- Where zones have been installed, check that the required
zones are turned on.
- If there is still no airflow from the outlets, contact your
installer, or call Seeley International Service on
1800 650 644.
No airflow from
outlets.
R6
- This may be normal operation due to low air flow.
- When the outlet temperature drops below a pre-set value the
cooling unit turns off to stop the cooling freezing. The cooling
unit re-starts after the outlet tempertature has increased
enough and the compressor re-start delay timer has elapsed.
- Increasing the fan speed will reduce the rate of cycling.
Cooling unit
cycles on and
off.