Owner`s manual

Heater operation
Using the FAN-only feature
- Turn the SCC OFF (press ON/OFF button if required).
- Press and hold the FAN button for 3 seconds - the heater fan
will start and increase to its maximum speed.
- To get air flow to zones (where fitted) press the
corresponding zone button.
- The fan speed is not adjustable in "FAN-only" mode.
- Press the ON/OFF button to turn the fan off.
Single SCC
systems
- Turn the "Master" SCC OFF (press ON/OFF button if
required).
- Press and hold the FAN button on the "Master" SCC for 3
seconds - the heater fan will start and increase to its
maximum speed.
- To get air flow to zones press the ON/OFF button on the
"Slave" SCC IN EACH REQUIRED ZONE to turn it on.
- The fan speed is not adjustable in "FAN-only" mode.
- To turn FAN-only mode off press the ON/OFF button on the
"Master" SCC.
Multiple SCC
systems
- With the SCC on press and hold the FAN button for 3
seconds.
- The fan speed and fan symbol will flash.
- Press the up or down arrow buttons to adjust to the required
fan speed.
- The SCC will revert to the normal ON state after a few
seconds.
- The fan speed is not user-adjustable:
- In multiple SCC systems, or
- With 3-star heaters.
Adjusting the
fan speed -
single SCC
systems only
Adjusting the fan speed
WED
ON
ZONE
1
2
3
WED
ON
Fan-only display
with no zones
enabled - single
SCC.
Fan-only display
with zones 1, 2 and
3 on - single SCC
with zones, or
multiple SCC
system.