10. Programming the Receiver Operating Frequency
& High Speed Conditioning of Fan Control
-- Important - Read This Section Carefully and Follow
the High Speed Conditioning Instructions Closely --
PROGRAMMING THE RECEIVER
OPERATING FREQUENCY & HIGH SPEED
CONDITIONING OF FAN CONTROL
IMPORTANT: Ceiling Fan Blades MUST be installed
before High Speed Conditioning can begin.
NOTE: If using a 3-way Switch Installation, ensure that
both Wall Controls are using the same Switch Code.
10.1
Turn the Wall Control ON/OFF Switch to the "OFF"
position.
Restore Electricity to the Ceiling Fan Branch Circuit at the
Circuit Breaker or Fuse Box.
Flip the Wall Control's ON/OFF Switch to "ON" position.
Within one minute of flipping the Switch to "ON", push
and hold the FAN OFF Button ( ) for 3 to 5 seconds to
set the Code in the Receiver. The Ceiling Fan Lights
(if installed) will blink to indicate the Wall Control Code has
been paired with the Receiver.
IMPORTANT: Immediately after successful pairing, the
Ceiling Fan will automatically begin High Speed
Conditioning of the Motor. During conditioning, the
Electronic Motor Control Software is calculating
Speeds for the 2nd through 5th Speed settings based
on the Blades that were installed on the Fan.
10.2
The Fan will run for approximately 2 minutes in the Upward
Direction then Reverse Direction to down flow and run an
additional 2 minutes. When Conditioning is complete, the
Fan will come to complete stop.
IMPORTANT: Do not interrupt the Conditioning until
the Fan comes to a complete stop in approximately
5 minutes. All functions of the Control will be rejected
during Conditioning.
10.3
High Speed Conditioning is now complete.
10.4
If programming is unsuccessful, retry the above
instructions after cycling the Wall Control ON/OFF Switch
to restart the 1 minute programming time period.
10.5
If still unsuccessful, shut off the Electricity at the Fuse Box
or Breaker Panel and change the Wall Control Frequency
(Section 8.2, Page 19). After changing the Frequency
Settings, repeat instructions 10.1 - 10.5 of this section
within one minute of restoring the Electricity.