Installation Instructions
InstallationInstructions
FORUSEONLYWITH12VLOWVOLTAGELANDSCAPEPOWERUNITSTHATDONOTEXCEED25AMPS,15VOLTMAXIMUM.
WARNING:
LUMINAIRESARENOTTOBEINSTALLEDWITHIN10FT.(3.05M)OFAPOOLORSPA.SECONDARYCABLEISNOTTOBEBURIEDMORE
THAN6”.WHENUSINGMULTIPLELUMINAIRES,LOADISNOTTOEXCEEDTHETOTALWATTSOFTRANSFORMERRATING.DONOTUSE
EXTENSIONCORDSONPOWERUNITS.
NOTE:
NOTE:
NOTE:
LuminairesmustbeinstalledinaccordancewiththeNationalElectricalCode(NEC)andlocalcodes.Failuretodosowill
voidthewarrantyandmayresultinseriousinjuryand/ordamagetotheluminaire.
AlwaysuseULrecognizedwireconnectorsforconnections.
1.Topreventelectricalshock,disconnecttransformerfromelectrical
supplybeforeinstallationorservice.
2.Digaholeapproximately3”diameterby2”deepatselectedlocation.
3.Removemountingplatefrombottomofluminaire
4.Attachgroundstaketomountingplatewith2screwssupplied
5.Thread18/2directburialwirethroughcenterofgroundstakeandout
exitholeofstake.
6.Connect18/2pigtailtomainpowercablewithconnectorsupllied.
Turnonpowersupplytotestconnection.
7.Pushgroundstakeintogroundsothatmountingplateislevelwith
ground.
8.Attachfixturetomountingplatewithscrewsprovided
Installationrequiresconduitsleevetoallow36” pigtailtoexit
throughconcretefooting.
1.Topreventelectricalshock,disconnecttransformerfromelectrical
supplybeforeinstallationorservice.
2.Digaholeapproximately12” diameterby6”deepatselected
location.
3.Installfoundationanchorstomountingplate.Positionconduitsleeve
tobecenterholeinmountingplate.
4.Usingstandardmasonryprocedures,supportbollardbaseinselected
locationmakingmountingplateremainaboveconcretegrade.
5.Pourconcretemakingsureexitendofconduitsleevereachesoutside
concrete.
6.Runwirepigtailthroughbottomsleeveandattachtomainpowersupply
cable
Luminairesaresuppliedwith36” of18-2cablepigtailforsecure
connectiontomainsupplycable.Wireistobeprotectedbyroutingin
closeproximitytoluminaire.Wiringshouldbeburiedamax.depthof6”
inordertoconnecttomainsupplycable.
7.Attachluminairetomountingplateandsecurewithnutssupplied
8.Providepowertoluminaireandcheckforproperoperation.
GroundStakeInstallation
ConcreteFootingInstallation
pathwaylightisprovidedwithagroundstaketo
facilitateanin-gradeinstallation.However,forapermanentandsecure
installationaconcretefootingsupportforbollardpostisrecommended.