Instruction Manual

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of
BRAY INTERNATIONAL, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer’s
detailed knowledge and experience with their application.
S98 O & M : 23
Series 98 Operation & Maintenance
11.0 Maximum Operating Pressure (cont.)
11.4 Spring Return (Bar)
MAXIMUM OPERATING PRESSURE FOR SPRING RETURN ACTUATOR - Symmetrical Yoke / Canted Yoke
Model
Rated Torq Cyl Size
Pressure, bar
S1 S2 S3 S4 S5
Nm Lb-in S C S C S C S C S C
45 E2 4500 39830
P08 10.3 10.3 10.3 10.3 10.3 10.3
P09 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3
P10 10.1 8.6 10.3 9.3 10.3 10.2 10.3 10.3
P12 7.0 6.0 7.4 6.4 8.1 7.1 8.4 7.4
P14 5.1 4.4 5.5 4.7 5.9 5.2 6.1 5.4
73 E2 7300 64612
P10 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3
P12 9.6 8.3 9.9 8.6 10.3 9.2 10.3 9.7
P14 7.0 6.1 7.3 6.3 7.7 6.7 8.1 7.1
P16 5.4 4.6 5.5 4.8 5.9 5.1 6.2 5.4
14 E3 14000 123914
P12 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3
P14 10.3 9.5 10.3 9.8 10.3 10.2 10.3 10.3 10.3 10.3
P16 8.4 7. 2 8.7 7.5 9.0 7.8 9.5 8.3 9.9 8.7
P18 6.6 5.7 6.8 5.9 7.1 6.1 7.5 6.6 7. 8 6.8
P20 5.4 4.6 5.5 4.8 5.7 5.0 6.1 5.3 6.3 5.5
24 E3 24000 212424
P14 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3
P16 10.3 9.5 10.3 10.0 10.3 10.3 10.3 10.3 10.3 10.3
P18 8.7 7.5 9.1 7.9 9.6 8.4 10.0 8.8 10.3 9.2
P20 7.0 6.1 7.3 6.4 7.8 6.8 8.1 7.1 8.4 7.4
P22 5.8 5.0 6.1 5.3 6.4 5.6 6.7 5.9 6.9 6.1
P24 4.9 4.2 5.1 4.4 5.4 4.7 5.6 4.9 5.8 5.1
45 E3 45000 398295
P18 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3
P20 10.3 9.2 10.3 9.5 10.3 10.2 10.3 10.3 10.3 10.3
P22 8.8 7.6 9.1 7.9 9.6 8.4 9.9 8.7 10.3 9.0
P24 7.4 6.4 7.6 6.6 8.1 7.0 8.3 7.3 8.6 7.6
P28 5.4 4.7 5.6 4.8 5.9 5.2 6.1 5.3 6.3 5.5