Series 98 Operation & Maintenance
11.0 Maximum Operating Pressure
MAXIMUM OPERATING PRESSURE FOR DOUBLE ACTING - SINGLE CYLINDER ACTUATOR - Symmetrical Yoke/Canted Yoke
Model
Rated Torq
Cyl
Nm Lb-in 8 9 10 12 14 16 18 20 22 24 28
45 E2 4,500 39,830
S 150 144 117 81 59
C 150 119 96 67 49
73 E2 7,300 64,612
S 150 107 78 60
C 127 88 65 49
14 E3 14,000 123,914
S 150 127 97 77 62
C 142 104 80 63 51
24 E3 24,000 212,424
S 150 124 98 80 66 55
C 134 102 81 66 54 46
45 E3 45,000 398,295
S 150 121 100 84 62
C 123 100 83 69 51
MAXIMUM OPERATING PRESSURE FOR DOUBLE ACTING - DUAL CYLINDER ACTUATOR - Symmetrical Yoke/Canted Yoke
Model
Rated Torq
CylNm Lb-in 8 9 10 12 14 16 18 20 22 24 28
45 E2 4,500 39,830
S 92 72 59 41
C 76 60 48
73 E2 7,300 64,612
S 77 54
C 64 44
14 E3 14,000 123,914
S 87 64 49
C 72 52 40
24 E3 24,000 212,424
S 82 63 49 40
C 67 52
45 E3 45,000 398,295
S 75 61 50 42
C 62 50 41
11.2 DD (Double Acting - Dual Cylinder)
11.1 DA (Double Acting - Single Cylinder)