Install Instructions
Table Of Contents
- Safety Instructions - Definition of Terms
- Hazard-Free Use
- Qualified Personnel
- Part Numbering System Reference Chart
- Introduction
- Actuation
- Storage
- Commissioning
- Disassembly and Assembly
- Field or Factory Installable Options
- Appendix A
- Appendix B
- Series 70 – Size 003, 006 – Electric Actuator Exploded View
- Series 70 – Size 008, 012, 020 – Electric Actuator Exploded View
- Series 70 – Size 030, 050, 065 – Electric Actuator Exploded View
- Series 70 – Size 130, 180 – Electric Actuator Exploded View
- Series 70 – Size 130, 180 – 3:1 Gear Box Exploded View
9
Series 70 Electric Actuator
Installation, Operation and Maintenance Manual
4. Lock the travel stop bolt in position with the locknut.
5. Manually drive the actuator to the ‘open’ position.
6. Once the actuator is in the ‘open’ position, rotate
the handwheel counterclockwise
• ½ turn for Actuator Size 003, 006.
• 1 turn for Actuator Size 008, 012, 020.
• ½ turn for Actuator Size 030, 050, 065.
• 2 turns for Actuator Size 130, 180.
7. Adjust the ‘open’ travel stop bolt until the travel
stop spacer is fully engaged or the travel stop bolt
contacts the output segment gear.
8. Lock the travel stop bolt in position with the locknut.