Dust Cap
Male Quick Disconnect
Adapter Fitting
Dust Plug
Female Quick Disconnect
Adapter Fitting
Installation Instructions
Step 9 – Install fittings
• Install fittings in order shown to ports as indicated by A and B.
• Thread O-ring side of adapter fittings into the valve ports A and B finger tight.
• Torque fittings to valve at 37-46 ft.-lb.
• Slip rubber straps of dust plug and cap over adapter fittings.
• CAUTION: Never back off an installed pipe fitting to achieve proper alignment.
Loosening installed pipe fittings will corrupt the seal and contribute to leakage and
failure.
• Apply thread sealant and screw finger-tight (2) quick disconnect fittings onto the
fittings installed into valve A and B ports. Which fitting is attached to which port
is up to the customer. Please refer to owner’s manual to determine direction of
flow and desired configuration of quick disconnect fittings.
• Hold adapter fitting and wrench-tighten the quick disconnect fitting to 1.5-3.0
Turns Past Finger Tight position. Properly assembled fittings total thread
engagement should be 3.5-6 turns.
• Press plug/cap into place.
Tools Needed
• Adjustable wrench
• 7/8 Deep Socket
• Torque Wrench
• Ratchet