User Manual
14
Battery
segments in the
display are
skipped with
decreasing
battery capacity.
Foil and cutter are worn
which requires more power
for each shave.
– Renew Foil & Cutter cassette.
– Regularly oil the shaving system,
especially when cleaning with water
only.
Shaving parts
have been
changed recently
but replacement
symbol lights up.
Reset button has not been
pushed.
Push the reset button for at least
3 seconds to reset the counter.
Shaver head is
damp.
1. Drying time after automatic
cleaning was too short.
2. Drain of the Clean&Renew
station is clogged.
3. Cleaning cartridge has
been used for quite a while.
1. Clean directly after shaving to allow
enough time for drying.
2. Clean the drain with a wooden
toothpick. Regularly wipe the tub
clean.
3. The ethanol/isopropanol proportion
has decreased while the oil
proportion has increased. Remove
residue with a cloth.
CLEAN&RENEW STATION
Cleaning does
not start when
pressing the
start button.
1. Shaver is not placed
properly in the
Clean&Renew station.
2. Cleaning cartridge contains
not enough cleaning fluid
(display lights red).
3. Appliance is in stand-by
mode.
1. Insert shaver into the Clean&Renew
station (contacts of the shaver need
to align with contacts in the station).
2. Insert new cleaning cartridge.
3. Press start button again.
Increased
consumption of
cleaning fluid.
Drain of the Clean&Renew
station is clogged.
– Clean the drain with a wooden
toothpick.
– Regularly wipe the tub clean.