Instructions / Assembly

WARNING: DO NOT stretch the connector to
make it t. Connector must be long enough to
allow the appliance to be positioned at its farthest
anticipated connected distance from the gas supply
without stretching, twisting or bending smaller that a
1-1/2 internal diameter (diameter of a golf ball).
WARNING: DO NOT trap connector against sharp
edges or corners.
CAUTION: DO NOT kink, twist or bend connector sharply.
6. Turn manual shut-off valve on to allow gas to enter system.
WARNING: DO NOT TURN ON APPLIANCE until all
connections have been leak tested!
WARNING: DO NOT USE matches, candles, open
ames or other sources of ignition to leak test
connections!
7. Test all connections with leak test solution provided,
or with clear soap and water solution; bubbles will
indicate a leak. If a leak is detected, turn off gas
supply before further tightening connections. Water
rinse and towel dry connector once test is complete.
8. Wait at least 10 minutes to be certain that all vapors
have dissipated. If leak test conrms connections do
not leak gas, and you do not smell any gas,
THEN light pilot(s) and turn on appliance.
Tools Needed for Installation:
• (2) 10 in. adjustable wrenches
• Pipe dope or gas pipe thread tape
• Leak detection solution
X
©2009, 2019 Brasscraft Manufacturing Company
325.01 Rev. 11/19
Brasscraft Manufacturing Co., 39600 Orchard Hill Place Novi, Michigan 48375-5331
TOLL-FREE: 877.272.7755 FAX: 248.305.6011 www.brasscraft.com
Manufacturer assumes no responsibility for failure due to improper installation.
©2019 Brasscraft Manufacturing Company, Novi, MI 48375-5331 U.S.A.
All Rights Reserved. www.brasscraft.com BrassCraft
®
brand is a trademark of Brasscraft Mfg. Co.
El fabricante no asume ninguna responsabilidad si la instalación no se hace de acuerdo al instructivo.
BrassCraft
®
brand es una marca registrada de Brasscraft Mfg. Co.
Gas Connector Maximum Flow Capacity
Part #
ID
Color Code
12 in 18 in 24 in 30 in 36 in 48 in 60 in 72 in
Gas Connector with Standard Fittings
CSSL
1/4 BTU’s 48,000 43,800 40,000 36,400 33,400 28,300 24,900 23,100
Purple Watts 14,067 12,837 11,723 10,668 9,789 8,294 7,297 6,770
CSSD
3/8 BTU’s 102,000 93,100 85,000 77,100 71,100 60,500 53,200 49,100
Green Watts 29,893 27,285 24,911 22,596 20,837 17,731 15,591 14,390
CSSC
1/2 BTU’s 180,000 164,200 150,000 136,000 125,000 106,000 93,200 86,000
Gold Watts 52,752 48,122 43,961 39,858 36,634 31,066 27,314 25,204
Safety+Plus® (Gas Connector with Excess Flow Valve Attached)
CSSL
1/4 BTU’s 42,000* 37,400* 36,800* 36,400 33,400 28,300 24,900 23,100
Purple Watts 12,308* 10,960* 10,784* 10,668 9,789 8,294 7,297 6,770
CSSD
3/8 BTU’s 102,000 93,100 85,000 77,100 71,100 60,500 53,200 49,100
Green Watts 29,893 27,285 24,911 22,596 20,837 17,731 15,591 14,390
CSSC
1/2 BTU’s 122,000* 118,000* 115,000* 111,000* 107,000* 106,000 93,200 86,000
Gold Watts 35,754* 34,581* 33,702* 32,530* 31,358* 31,066 27,314 25,204
*
Note: Connecting the safety valve lowers these values below the Z21.24/CSA 6.10 and Z21.75/CSA 6.27 standards
Listings & Certications:
Components CSA listed to ANSI Z21.24 / CSA 6.10 standard “Connectors for
Gas Appliances”
Components CSA listed to ANSI Z21.75 / CSA 6.27 standard “Connectors for
Outdoor Gas Appliances & Manufactured Homes”
NOTE: This connector meets or exceeds the minimum allowable capacity
as determined under test conditions specified in ANSI Z21.24 • CSA 6.10.
Straight length capacity rated in BTU per hr. using: 0.64 SP. Gr., 1000 BTU per
Cu Ft. Gas at 0.50 inch Water Column Pressure Drop. The capacity at 50 Pa
(0.2 inch water column) pressure drop can be determined by multiplying the
BTU per hr. listed in the table above by 0.632
.