SPECIFICATIONS
TECHNICAL DATA SHEETS
Use: For use with natural, manufactured, mixed, liqueed petroleum gases, and LP gas-air mixtures.
Design Features:
Helps prevent gas fires & explosions due to gas line ruptures or disconnects at
the appliance
Automatic valve activation immediately restricts gas ow to a non-hazardous
level to help avert a dangerous build up of gas in the home
Automatic reset once the gas line has been properly repaired
24 hour, maintenance-free protection for the life of the product with no parts
to wear, break, or misalign over time
100% performance tested
Operating Specications:
Temperature: 32° - 150° F
Pressure: 1/2 PSI maximum
Installation:
Omni-directional: install in any orientation, horizontal to vertical
MATERIAL SPECIFICATIONS
Valve Body
Brass
Magnet
Rare earth
Plate
Stainless steel
Seat
Brass
Cartridge Body
POM
*All Safety+PLUS valves require a minimum inlet pressure of 4” W.C. Flow rates given are 0.6 specic gravity natural gas
with an average heating value of 1,000 Btu per cubic foot; therefore, 1 kBtu/h is equal to 1 SCFH (standard cubic foot per
hour).
**When installed in the vertical downward position (arrows pointing toward oor), the closing ow rate is 110,000 Btu/h @
0.6” WC
Listings & Certications:
IAPMO listed to CSA-US 3.92 standard “Excess Flow Valves” (file #42
13)
CSA listed to CSA-US 3.92 standard “Excess Flow Valves” (le # 204593)
California Division of State Architects listed to CSA-US 3.92 standard
“Excess Flow Valves” (le# CA-DSA 02 02)
City of Los Angeles
COPPER WATER HEATER CONNECTORS
SAFETY+PLUS
®
APPLIANCE GAS EXCESS FLOW VALVE
FLOW CAPACITY
OD Cartridge
Label
Color
Minimum Flow
Rate
Maximum Flow
Rate
Closing Flow Rate
Bypass Flow
Rate
5/8” 1560 Gold 75,000 135,000 @ 0.5” WC 195,000 @ 0.7” WC < 5 SCFH
5/8” 1550 Tan 60,501 102,000 @ 0.5” WC 135,000*@ 0.6” WC < 5 SCFH
1/2” 1550 Lime 60,501 102,000 135,000** < 5 SCFH
1/2” 1540 Teal -------- 60,500 95,000 < 5 SCFH
3/8” 1540 Lilac -------- 48,000 95,000 < 5 SCFH