Instructions / Assembly

FLEXIBLE
CONNECTOR
Conector exible
COMPRESSION NUT
Tuerca de compresión
VALVE OUTLET
Salida de la llave
de paso
STOP
Llave de paso
COMPRESSION
SLEEVE
Manga de
compresión
PEX TUBE
Tubo de PEX
TUBE INSERT
(IF NEEDED)
Inserto para tubería
COMPRESSION
NUT
Tuerca de
compresión
STOP OUTLET
Salida de la llave
de paso
STOP
Llave de paso
FLEXIBLE NUT X NUT CONNECTOR
Be sure to shut off water before starting.
CAUTION:
BE SURE TO IDENTIFY THE CORRECT WATER SUPPLY CONNECTION
BEFORE BEGINNING INSTALLATION PROCEDURE. APPLICATION OF THIS CONNECTOR
WITH THE INCORRECT WATER SUPPLY CONNECTION MAY CAUSE LEAKS.
1. Shut off water supply at stop.
2. Remove old supply tubes.
3. Thread wing nut of connector onto
faucet shank or toilet ballcock and
hand tighten only. For connectors
with metal nuts, hand tighten, then
wrench tighten 1/4 turn more.
CAUTION: DO NOT OVERTIGHTEN
as this could lead to future failure.
Tools Needed for Installation:
Wrench • Protective cloth
NOTE: Connector includes washers,
DO NOT USE THREAD SEALANT.
COPPER COMPRESSION OUTLET (CONTINUED)
5. If using a thread sealant, apply a thin even coat to the male compression threads
only taking care not to get thread sealant on the compression ring or sealing
surface. IMPORTANT: Excessive thread sealant may cause joint to fail.
6. Hand tighten the compression nut onto the stop as far as it will allow.
7. Using hand tools, tighten 1 to 1-1/4 turns from the hand tight position.
Note: Make sure that the riser remains seated and square to the stop. If the riser
is not square to the stop, this could affect the ability to get a good connection.
CAUTION: DO NOT OVERTIGHTEN as this could lead to future failure.
8. For inlet tube installation, see that section.
Tools Needed for Installation: • Wrench • Tube Cutter
PEX COMPRESSION OUTLET
Be sure to shut off water before starting.
NOTE: On 3/8 in. OD and smaller, use plastic compression sleeve. On tubing larger than
3/8 in. OD, use brass compression sleeve w/stainless steel tube insert.
1. Cut the riser tube to length so it
bottoms out in the stop.
2. Place compression nut and
sleeve onto the PEX tube.
3. If larger than 3/8 in. OD, insert
stainless steel tube insert.
4. A drop of general purpose oil will
make tightening easier.
5. If using a drop of oil or thread
sealant be sure the threads are
clean of any debris and that
sealant is also free of any metal
debris. DO NOT USE a putty,
gasket material or thread
seal tape.
6. If using a thread sealant, apply a thin even coat to the male compression threads
only taking care not to get thread sealant on the compression ring or sealing
surface. IMPORTANT: Excessive thread sealant may cause joint to fail.
7. Hand tighten the compression nut onto the stop as far as it will allow.
8. Using hand tools, tighten 1-1/2 to 2 turns from the hand tight position. Note: Make
sure that the riser remains seated and square to the stop. If the riser is not square
to the stop, this could affect the ability to get a good connection. CAUTION: DO NOT
OVERTIGHTEN as this could lead to future failure
9. For inlet tube installation, see that section.
Tools Needed for Installation: • Wrench •Tube Cutter General Purpose Oil
425.04 Rev. 11/19
Brasscraft Manufacturing Co., 39600 Orchard Hill Place Novi, Michigan 48375-5331
TOLL-FREE: 877.272.7755 FAX: 248.305.6011 www.brasscraft.com
Manufacturer assumes no responsibility for failure due to improper installation.
©2019 Brasscraft Manufacturing Company, Novi, MI 48375-5331 U.S.A.
All Rights Reserved. www.brasscraft.com Designed, Machined and Assembled in the U.S.A.
BrassCraft
®
brand is a trademark of Brasscraft Mfg. Co.
El fabricante no asume ninguna responsabilidad si la instalación no se hace de acuerdo al instructivo.
Diseñado, Maquinado y Ensamblado en E.U.A. BrassCraft
®
brand es una marca registrada de Brasscraft Mfg. Co.
©2019 Brasscraft Manufacturing Company