Specifications

S83/85 Ultrasonic Generator System Installation
A40-064 Rev 0 Page 62
5.9.6 CB-Type Immersible Transducers – 36-Element
Figure 5-26 Wiring 3 CB Type Immersible Transducers
ID Label
RF Cable
S8XXX − XX
J1
Assembly
S8000 RF Cable
Wiring Diagram
(BLK)
Transducers
Immersible
+ +
(RED)
(GRN/YEL)
3
(BLK)
J1
J1
2
1
3
1
2
(RED)
J1
+
(RED)
(RED)
(BLK)
(BLK)
To Immersibles
RF Cables From
CB−type Immersible Transducers
RF+ (RED)
RF− (BLK)
GND (GRN/YEL)
Note: After installing, test grounds and continuity according to local codes.