5.9.2 Mounting a CB-Type Immersible Transducer
Figure 5-22 Mounting CB Type Immersible Transducers
CB,EB,SB
Immersible
Transducer
Fitting
Teflon
Washer
Tank Wall
Metal Washer
Nut
To mount an immersible transducer, follow these steps:
Step Action
1 Select a location for the immersible transducer (Refer to Do’s and
Don’ts).
2 Measure and mark two places for the mounting hole(s).
3 Place the Teflon washer on, then put through holes.
4 Place the cable in desired position.
5 Attach the immersible transducer to the tank sidewall as follows:
1. Insert the two immersible transducer fittings through holes.
2. Attach the washer and jam nut to the fittings and tighten
until the washer seats.
6 Route the immersible transducer cable to the junction box (follow
wiring instructions) or the ultrasonic power supply.